Flames rising against a white intumescent-coated structural steel beam, the coating protecting the steel

We buysteel time.

Fire protection buys the minutes between steel losing strength and a building losing its people — measured, recorded, defensible.

Steel is strong
until it is hot.

Around 550°C an unprotected member can no longer carry what it was designed to hold. A fire resistance rating is the number of minutes we keep the steel below that line.

The thickness that buys those minutes is not a guess — it is calculated per member from the rating and the section factor, and issued by the coating manufacturer as a loading schedule. We apply to that schedule and prove it afterwards.

Indicative curve of structural steel strength against temperature, with the 550 degree limiting temperature marked 100%50%0% 20°C400°C700°C STRENGTH RETAINED — INDICATIVE 550°C LIMITING TEMPERATURE

Why builders hand us the steel.

Schedule-first

Nothing is guessed — thickness comes off the manufacturer's loading schedule, per member.

Conditions gated

Substrate temperature, humidity and dew margin logged before any coat goes on.

Measured, member by member

DFT recorded against each member — not sampled by area, not reconstructed later.

System integrity

Primer, fire and finish kept as one compatible system, never mixed across brands.

Windows held

Recoat intervals and drying windows planned into the programme, not discovered on site.

Certifier-ready

Producer statements at completion, backed by the full measurement record.

30–120FRR MINUTES APPLIED
PER MEMBERDFT RECORDED
SHOP + SITEAPPLICATION
NZ WIDECOVERAGE
RATING — WHAT IT BUYS

Buy the minutes back.

Move through the ratings. Illustrative only — your rating comes from the fire engineer; the thickness that delivers it comes from the manufacturer's loading schedule for your members.

60 minutes of rated protection

The coating reacts, expands and forms an insulating char layer across the section. The steel behind it stays below its limiting temperature for the rated period, so the member keeps carrying load while the building empties.

Char thickness shown is schematic, recorded against each member on the QA schedule in practice.

Drawing detail: section through a coated steel beam showing the char layer at the selected rating, with dimension callouts FLANGE b DEPTH d CHAR — FRR 60 DETAIL A — PROTECTED SECTION FRR 60 · SCALE NTS

Four things we do to steel.

QA — THE RECORD

A coating you can't prove is a coating that didn't happen.

Once the ceiling goes in, nobody can inspect fire protection again. What survives is the record — which member, what thickness, measured with what, calibrated when. That record is what the certifier signs against.

Dry film thickness gauge reading 851 microns against coated structural steel on site
The 851 µm reading in the record — as measured on site.

The paperwork that survives the ceiling.

Specimen formats only — the documents your certifier receives, shown as shapes, not project data.

How every job runs.

Documents

LOADING SCHEDULE IN

Preparation

CLASS + PROFILE SIGNED

Application

WITHIN WINDOWS

Verification

DFT PER MEMBER

Handover

PRODUCER STATEMENT

Experience

Work completed by our people before Steel Coating Solutions Limited was incorporated in August 2026 — shown as evidence of what the team has done, not as projects delivered by the company.

Spray pump and operator set up on a concrete deck
Pump set-up and material handling on deck.
Coated steel frame through a building services zone
Coated frame through a services zone.
Depth pin gauge held against sprayed cementitious
Depth-pin verification on cementitious.

The full gallery

SYSTEMS — MANUFACTURERS

Systems we apply

Applied to the manufacturer's specification, with the loading schedule issued for the project's specific members.

ALTEX
PENDING CONFIRMATION
SLOT 2
PENDING CONFIRMATION
SLOT 3
PENDING CONFIRMATION
SLOT 4
PENDING CONFIRMATION

Send us the drawings.
We'll tell you what's missing.

Email the fire report, the structural drawings with the steel schedule, and the coatings specification. Partial is fine — we reply with what's missing rather than sitting on it.